7, No socket connection to license server manager service. -8, Invalid (inconsistent) license key or signature. The license key/signature and data for the feature do not match. This usually happens when a license file has been altered. -9, Invalid host. The hostid of this system does not match the hostid specified in the license.

A SOLIDWORKS network license requires a network connection between the server and client machines. The server runs the SolidNetWork License Manager service and client machines must verify a connection and available licenses from the server before SOLIDWORKS will open.

Communication errors are commonly found on first setting up a network license or if there are changes to the network.Here are a few possible error messages that may be seen on a client machine when trying to open SOLIDWORKS.ServerThe SolidNetWork License Manager needs to be installed, activated and started on the server. The major version needs to be the same or newer than SOLIDWORKS running on the client machines. It is backwards compatible so you should always upgrade the License Manager before SOLIDWORKS. For example you can use a 2019 License Manager while running SOLIDWORKS 2018.After any upgrade to the License Manager, you must reactivate to obtain the latest license version.Service StartedVerify that the SolidNetWork License Manager service is running. Open the License Manager and click ‘Start’ if applicable. You can also check Windows Services to verify the service has been started and set to Automatic startup.

Invalid inconsistent license key solidworks viewer download

SOLIDWORKS SolidNetWork License Manager Service Firewall SettingsThe most common source of communication errors are due to firewalls blocking the required ports. If you do have firewalls setup on your network, you will need to select the option that ‘ A firewall is in use on this server‘ while activating. This switches the License Manager to use a static vendor daemon port in order to specify the specific port in the firewall. By default the License Manager uses TCP ports 25734 and 25735. These can be changed if required.To access these options again, you can go through the same. SOLIDWORKS Network License Manager PortsBoth ports 25734 and 25735 must be opened through the firewall for both Inbound and Outbound communication. Windows Firewall RulesThough not typically required with the default Windows Firewall, you may need to apply a rule to allow connection for programs lmgrd.exe and swd.exe.

By default these programs are located under C:Program Files (x86)SolidWorks SolidNetWork License Manager. ClientAs mentioned, client machines must be able to communicate with the server before a SOLIDWORKS license can be obtained. The firewall ports will need to opened in the same manner as the server. SOLIDWORKS SolidNetWork License Manager ClientYou can also test entering the server IP address instead of the server name to see if there is an issue with name resolution.If you still receive errors on opening SOLIDWORKS, there are several tests you can perform to verify the connection is valid. Ping TestThe Ping test verifies that you have access to the server over the network.

Solidworks Viewer 32 Bit

This will also give you an indication of the speed of connection from the response time (latency). If the test fails, you will need to check your network connection on both machines. Open the Windows Command Prompt (click Start and type CMD). Type in ping servername (where “servername” is the name of your server or the IP address). It should give a response that 4 packets were sent and 4 were received with 0% loss to verify you have a connection. Windows Ping TestThe speed in milliseconds will be given to determine the latency. This should be a low as possible.

Httpwatch professional v8.5.27 incl licence code License: Freeware / $0.

If it shows more than 100ms, this indicates a very slow connection and may fail to obtain a license due to a default timeout. Have your IT troubleshoot the slow performance of the network. Telnet TestThe Telnet test allows you to verify that ports 25734 and 25735 have been opened properly.

Solidworks Viewer Online

Follow the steps outlined in our article Connectivity ToolAlthough typically used to troubleshoot SOLIDWORKS PDM connections, the Connectivity Test Tool can be used to test for the SNL Server connection only. To find out where the tool can be downloaded, read our blog article.

Invalid Inconsistent License Key Solidworks Viewer Download

Error: FLEXlm error: -8 Invalid (inconsistent) license key Error MessageWhile installing ArcInfo 8.x, with ArcInfo 7.x keycodes, the following error may occur:FLEXlm error: -8 Invalid (inconsistent) license key. Note:This article pertains to ArcGIS versions 8.x. Later versions of ArcGIS may contain different functionality, as well as different names and locations for menus, commands and geoprocessing tools. CauseThe license key and data for the FEATURE do not match. This usually happens when a license file has been altered. Solution or WorkaroundContact ESRI Customer Service to upgrade your keycodes to ArcInfo 8.x.